Custom Power Supplies
Custom Industrial Power Supplies


500 Watt IP67 Industrial Grade Power Supply

Product Description

500 Watt IP67 Industrial Grade Power Supply This 500 watt, single output, IP67, industrial grade ac to dc power supply is designed for applications requiring a water resistant unit that can operate in an outdoor environment.  With a calculated MTBF in excess of 500,000 hours, this supply offers extreme reliability and is very suitable for remote operations.  

Features

  • Meets IP67 Waterproof Standards
  • Operating Temperature Range: -40º to +70º C
  • Compact Size: 4.5” x 5.5” x 9.0”
  • Calculated MTBF: 500,000 hours
AC Input
  • Voltage Input Range: 90-264VAC (nominal range)
  • Frequency: 47-440Hz
  • Phase: Single Phase, 2 wire plus ground
  • Inrush Current: <40A  (Cold Start at 200Vac)
  • Power Factor Correction: .95 minimum, meets EN61000-3-2
  • Start-Up Time: <500mSec (Output within regulation)
  • Input Surge Voltage: Input transient suppression circuitry to protect power supply from permanent damage.

Output Selection Guide

Model #:

Voltage

Max Current

Regulation

Ripple

IP67IPS500-3.3

3.3Vdc

41.6 Amps

±3%

50mV pk-pk

IP67IPS500-5

5.0Vdc

41.6 Amps

±3%

50mV pk-pk

IP67IPS500-9

9.0Vdc

41.6 Amps

±1%

120mV pk-pk

IP67IPS500-12

12Vdc

41.6 Amps

±1%

120mV pk-pk

IP67IPS500-15

15Vdc

33.3 Amps

±1%

150mV pk-pk

IP67IPS500-19

19Vdc

26.3 Amps

±1%

150mV pk-pk

IP67IPS500-24

24Vdc

20.8 Amps

±1%

240mV pk-pk

IP67IPS500-28

28Vdc

17.8 Amps

±1%

240mV pk-pk

IP67IPS500-36

36Vdc

13.9 Amps

±1%

240mV pk-pk

IP67IPS500-48

48Vdc

10.4 Amps

±1%

240mV pk-pk

Note: Alternate output voltages are available, consult factory for availability.


DC Output Characteristics
  • Line Regulation: ±1.0% typical
  • Load Regulation: ±0.50% typical (No load to full load; nominal input)
  • Output Ripple/Noise: 1% typical (P-P; nominal input; full load; 20MHz bandwidth)
  • Set Point Accuracy: ± 2.0% of output voltage (Nominal input; full load; 25°C)
  • Transient Response: 3% 250 uSec recovery to 1% for 25% step load range from 75% to 100%
  • Overshoot: Turn-on and turn-off overshoot should not exceed 5% over nominal voltage.

Electrical Characteristics

  • Efficiency: 88% Minimum (Measuring at 115Vac and full load)
  • Turn On Delay:1 second maximum at 115 Vac
  • Hold-Up Time: None
  • Isolation Voltage:
    • Input to Output: 3000Vrms
    • Input to Baseplate: 2500Vrms
    • Output to Baseplate: 1500Vrms
  • Isolation Resistance: 10Mohms (Output to baseplate), 25ºC ambient 70%RH
  • Temperature Regulation: ±-2.0%/ºC (±.005%/ ºC max; over operating temp range)

Protection

  • Over Current Limit: 105-140% of full load (Automatic recovery)
  • Over-Voltage Protection: 125-145% of nominal output voltage (Latching)
  • Short Circuit: Auto-Recovery after short circuit condition is removed.
  • Over temperature Protection: The power supply is protected for over temperature conditions with thermal shutdown. Auto-Recovery when temperature returns to normal.
Environmental
  • Operating Temperature: -40º to +70º C
  • Storage Temperature: -40º to 100º C
  • Operating Humidity: 20% to 95% RH, Non-condensing
  • Storage Humidity: 10% to 95% RH, Non-condensing
  • Operating Altitude: Sea-level to 40,000 ft. in pressurized environment
  • Vibration: Operating: 15g-RMS, random, tri-axial vibration for 1 hr
  • Shock: Operating: 5G, half sine, 11msec, 3 axes. Non-Operating: 15G, half sine, 11msec, 3 axes.
  • Conducted EMI: EN 55022 Class B compliant (May require additional components)
  • Safety Certifications: Designed to meet cUL (UL60950-1/CSA60950-1),  TUV (EN60950-1) & CE (LVD)
  • Cooling: Conduction

Mechanical

  • Outline Dimensions: 4.5" X 5.5" X 9.0" (H X W X L)
  • Weight: ~16.0 oz. (454 grams)
  • I/O Connectors: Terminal pins

Optional Control and Alarms

  • Output Inhibit

Notes

  • Product specifications subject to change without notice. All rights reserved.
  • The information and specifications contained in this document are believed to be correct and accurate at the time of publication. DSC Power Solutions, Inc. accepts no responsibility for consequences arising from printing errors or inaccuracies pertaining to any use or application of this document.